[PARPORT] HP7100e plus - write error - loss of streaming

From: Barry Chase (bsc7080@mindspring.com)
Date: Thu Apr 27 2000 - 23:33:00 EDT

  • Next message: Barry Chase: "Re: [PARPORT] HP7100e plus - write error - loss of streaming"

    Okay I am back.. compiled and installed v.1.8.1 still giving me fits.
    Here is what I have... question is, Is there a diagnostic utility that I
    can run under linux to test the unit. How do I know if the cdrw unit is
    good ? I mean I can blank a cd, but I can't record. Is there a big
    difference in what it does during blank vs writing ?

    cdrecord -v speed=2 dev=0,0 04262000-1.iso

    Cdrecord 1.8.1 (i586-pc-linux-gnu) Copyright (C) 1995-2000 Jörg Schilling
    TOC Type: 1 = CD-ROM
    scsidev: '0,0'
    scsibus: 0 target: 0 lun: 0
    Using libscg version 'schily-0.1'
    atapi: 1
    Device type : Removable CD-ROM
    Version : 0
    Response Format: 1
    Vendor_info : 'HP '
    Identifikation : 'CD-Writer+ 7100 '
    Revision : '3.01'
    Device seems to be: Generic mmc CD-RW.
    Using generic SCSI-3/mmc CD-R driver (mmc_cdr).
    Driver flags : SWABAUDIO
    Drive buf size : 786432 = 768 KB
    FIFO size : 4194304 = 4096 KB
    Track 01: data 66 MB
    Total size: 76 MB (07:35.36) = 34152 sectors
    Lout start: 76 MB (07:37/27) = 34152 sectors
    Current Secsize: 2048
    Trying to clear drive status.
    cdrecord: Drive needs to reload the media to return to proper status.
       ATIP start of lead in: -11079 (97:34/21)
       ATIP start of lead out: 336075 (74:43/00)
    Disk type: phase change
    Manuf. index: 11
    Manufacturer: Mitsubishi Chemical Corporation
    Blocks total: 336075 Blocks current: 336075 Blocks remaining: 301923
    Starting to write CD/DVD at speed 2 in write mode for single session.
    Last chance to quit, starting real write in 1 seconds.
    Waiting for reader process to fill input buffer ... input buffer ready.
    Performing OPC...
    Starting new track at sector: 0
    Track 01: 3 of 66 MB written (fifo 43%).cdrecord: Input/output error.
    write_g1: scsi sendcmd: retryable error
    CDB: 2A 00 00 00 07 60 00 00 10 00
    status: 0x2 (CHECK CONDITION)
    Sense Bytes: F0 00 03 00 00 00 00 19 00 00 0A DF 0C 09 00 00 FF FF
    Sense Key: 0x3 Medium Error, Segment 0
    Sense Code: 0x0C Qual 0x09 (write error - loss of streaming) Fru 0x0
    Sense flags: Blk 0 (valid)

    write track data: error after 3866624 bytes
    Sense Bytes: F0 00 00 00 00 00 00 19 00 00 0A F0 00 00 00 00 FF FF
    Writing time: 28.046s
    Fixating...

    -- To unsubscribe, send mail to: linux-parport-request@torque.net --
    -- with the single word "unsubscribe" in the body of the message. --



    This archive was generated by hypermail 2b29 : Thu Apr 27 2000 - 23:37:09 EDT