Re: [PARPORT] cdrecord 1.10 (write error - loss of streaming) problem

From: schilling@fokus.gmd.de
Date: Fri Mar 02 2001 - 12:00:43 EST

  • Next message: T K: "Re: [PARPORT] cdrecord 1.10 (write error - loss of streaming) problem"

    >From zoerg@zworg.com Fri Mar 2 16:40:33 2001

    >schilling@fokus.gmd.de wrote:
    >> >Starting new track at sector: 0
    >> >Track 01: 19 of 302 MB written (fifo 0%).cdrecord: Input/output
    >> >error. write_g1: scsi sendcmd: retryable error
    >> >CDB: 2A 00 00 00 27 60 00 00 10 00
    >> >status: 0x2 (CHECK CONDITION)
    >> >Sense Bytes: F0 00 03 00 00 00 00 19 00 00 29 04 0C 09 00 00 FF FF
    >> >Sense Key: 0x3 Medium Error, Segment 0
    >> >Sense Code: 0x0C Qual 0x09 (write error - loss of streaming) Fru 0x0
    >> >Sense flags: Blk 0 (valid)
    >>
    >> This is a buffer underrun - most likely caysed by a misconfigured
    >> parallel port.
    >>
    >> Read README.parallel

    >I went through the README's but perhaps I have overlooked something.
    >>From the kernel log I get:

    The important thing is that you must set up the PP chip for EPP

    Jörg

     EMail:joerg@schily.isdn.cs.tu-berlin.de (home) Jörg Schilling D-13353 Berlin
           js@cs.tu-berlin.de (uni) If you don't have iso-8859-1
           schilling@fokus.gmd.de (work) chars I am J"org Schilling
     URL: http://www.fokus.gmd.de/usr/schilling ftp://ftp.fokus.gmd.de/pub/unix

    -- To unsubscribe, send mail to: linux-parport-request@torque.net --
    -- with the single word "unsubscribe" in the body of the message. --



    This archive was generated by hypermail 2b29 : Fri Mar 02 2001 - 12:02:43 EST